Description
The Stryker Neptune 2 Waste Management System is a closed fluid waste and smoke evacuation system. The mobile unit collects surgical waste from operating rooms. The Neptune 2 can also capture and eliminate smoke at the same time. The waste management system help disposes of Medical OR waste while reducing exposure to surgical fluids.
Stryker Neptune 2 Specifications:
General
- Brand: Stryker
- Model: Neptune 2
- Category: Electrosurgical Equipment
- Dimensions: 16 x 23 x 23 in (HxWxD)
- Weight: 43 kg
Water Requirements
- Pressure Range: 345 kPa to 827 kPa (50 to 120 psi)
- Temperature Range: 40 °F to 110 °F (4.4 to 43.3 °C)
- Fitting Connection: The facility source is equipped with a 3/4” Male (garden) Hose Thread (MHT) fitting and has a dedicated shutoff valve.
- Water quality: potable tap water
- Water Usage: Approximately 34 litres (9 gallons) per rinse cycle at default settings on standard cycle; water usage fluctuates due to selected cycle and facility flow.
Water Inlet Hose
- Inner Diameter: 0.50 in ( 1.27 cm)
- Length: 6ft (1.83 m)
Waste Outlet Hose
- Inner Diameter: 1 in (25.4 cm)
- Length: 6 ft (1.83 m)
Environmental
- Operation Temperature Limitation: 50°F to 104°F (10°C to 40°C)
- Operation Humidity Limitation: 30% to 75%
- Atmospheric Pressure Limitations: 70 kPa to 106 kPa
- Storage and Transportation Temperature: -4°F to 104°F (-20°C to 40°C)
- Storage and Transportation Humidity: 10 to 75 %
- Storage and Transportation Atmospheric Pressure: 50 kPa to kPa
Features:
- SealShut Technology is constantly closed during cases, manifold changes, docking and transport.
- Systematic containment reduces fluid contact with staff and the floor.
- Permits patient-to-patient use (Manifolds are single use).
- Clearly defines and displays low, medium and high suction and audibly alerts and visually displays when on high suction.
- Provides two independently adjustable suction sources, one for each canister.
- Powered IV pole for four 3000mL bags; self-retracts when turned off.
- Helps to optimize operating room turnover time, scheduling and volume.
** All used goods are reconditioned by Tomlin Medical Pty Ltd. Used goods are not endorsed or supplied by their original manufacturer and are not subject to any manufacturer warranty. All used goods are subject to the limited warranty provided by Tomlin Medical Pty Ltd.**
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.