Description
Caring for low birth weight neonates requires creating the best possible thermal-neutral environment. The Drager Isolette C2000 Infant Incubator helps to promote and foster neonatal care by delivering a heated and humidified environment.
Dräger Isolette C2000 Specifications:
General
- Brand: Dräger
- Category: Incubators
- Model: C2000
Size
- Height: 140 cm (55″)
- Width: 120.6 cm (47.5″)
- Depth: 75 cm (29.5″)
- Weight: 95.5 kg (210 lb)
Hood
- Access panel opening height: 28.0 cm (11″)
- Mattress tray size :40.6 x 81 cm (16 x 32″)
- Mattress to hood height: 41.2 cm (16.25″)
- Mattress size : 38.1 cm x 73.66 cm (15 in x 29″)
- Mattress tilt: ±12 ° (±1 °), continuously variable
Standard hood includes
- front and rear access panel
- 4 access ports and 2 iris ports
- 3 left and 3 right tubing grommets – front
- 2 left and 2 right tubing grommets – rear
Cabinet
- Casters: 4 casters, 12.7 cm (5″) and 2 casters with friction brake
- Storage volume: Approx. 80 l
- Recessed depth: 15 cm recessed cabinet
- Front-loading cabinet doors: 2
- Door closing mechanism: Soft-stop hinges
- The opening angle of the doors: > 90°
Cabinet Stand Accessories
- Gas tank mount
- Shelf
- IV Pole
Controller System
- Algorithm type of the Servo Control System: PID (Proportional Differential Integral) control algorithm
- Controller with LCD: With brightness control
- Selectable colour combinations: White on blue background (default) or yellow on black background
- RS-232 output: Yes
- Keypad lock: Yes
Temperature Control Modes
- Temperature control modes: Skin and air temperature control mode
- Air mode control temperature range: 20°C (68°F) to 37°C (98.6°F)
- Air mode control override temp range: 37°C (98.6°F) to 39°C (102.2°F)
- Skin mode control temperature range: 34°C (93.2°F) to 37°C (98.6°F)
- Skin mode control override temp range: 37°C (98.6°F) to 38°C (100.4°F)
- Dual-skin temperature monitoring: Yes
Features
- Optional Dual Access Doors – Allow access from either side, expediting care.
- Thermal Performance – Patented dual air curtains reduce radiant heat loss from the infant by warming the inner hood surface. A bi-directional airflow feature helps minimize temperature fluctuations when open access doors.
- Large Mattress and Dual Probes – The C2000 incubator allows for simultaneous care of twins in the same unit, allowing more incubators for more patients.
- Internal Noise Level less than or equal to 47dBA – Maintains a supportive environment for both patient and caregiver.
- Optional In-bed Scale – Weigh the baby in a warm environment with minimal disturbance.
- 24-hour Data Trends – This unit facilitates record-keeping for air and skin temperature, oxygen, humidity, heater power, and weight changes.
** All used goods are reconditioned by Tomlin Medical Pty Ltd. Used goods are not endorsed or supplied by their original manufacturer and are not subject to any manufacturer warranty. All used goods are subject to the limited warranty provided by Tomlin Medical Pty Ltd.**